3Com 3C780 User Guide - Page 97
set le, cutoff
![]() |
UPC - 662705029917
View all 3Com 3C780 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
4-10 Setting Up the Hub LER_Cutoff. This threshold is the link error rate at which a faulty or poor link connection will be broken. The factory-set default is 10.E-07 (10-7). If the LER exceeds the limits set by this option, the hub will automatically reestablish the connection to this port. If this is not possible, the port will be bypassed until the fault is corrected. To change the LER_Cutoff parameter, follow these steps: 1. Enter the set ler cutoff command. Type: set ler cutoff [Enter] You are prompted for the module number and the port number. Module? Port? The current LER values are displayed, followed by a prompt for your response. For example: Current LER Alarm exponent = 8 Current LER Cutoff exponent = 7 LER cutoff [4...8]? 2. Enter the new LER cutoff value. For example, type: 7 [Enter] If you enter a cutoff value that is more than the current alarm value, this message appears: Error: The cutoff exponent must be