3Com 3C780 User Guide - Page 84

Refer to the Setting Attachment Port Configurations

Page 84 highlights

3-16 Configuring the Hub All three types of port modules can be installed in slot 1. The type of module you install depends on the medium you are using to connect the hub to the next node. Table 3-5 shows how to configure each module for the type of attachment desired and what additional equipment or action is necessary to complete the connection. (Refer to the section "Setting Attachment Port Configurations" in Chapter 4 for information about configuring the attachment ports.) For example, if you want to establish either a dual attachment or a dual homed connection, configure the module's attachment ports as B/A. For a single attachment connection, configure the module's attachment ports as S/M. For a null attachment, set the attachment ports as M/M. To discover the configuration of the attachment ports on the module in slot 1, check the ATTACH LED display on the management module or enter the show attach command. The ATTACH LED is lit whenever there is a module installed in slot 1. Table 3-5. Configuring Modules Module Attachment Type Attachment Additional Port Equipment Configuration Required Fiber Dual B/A None Dual homing B/A Single S/M None None Null M/M None STP Dual B/A Dual homing B/A 2 Cascade connectors 2 Cascade connectors Single S/M 1 Cascade connector Null M/M None (continued)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176

3-16
Configuring the Hub
All three types of port modules can be installed in slot 1.
The type of module
you install depends on the medium you are using to connect the hub to the next
node.
Table 3-5 shows how to configure each module for the type of attachment
desired and what additional equipment or action is necessary to complete the
connection.
(Refer to the section “Setting Attachment Port Configurations” in
Chapter 4 for information about configuring the attachment ports.)
For example, if you want to establish either a dual attachment or a dual homed
connection, configure the module’s attachment ports as B/A.
For a single
attachment connection, configure the module’s attachment ports as S/M.
For a
null attachment, set the attachment ports as M/M.
To discover the configuration of the attachment ports on the module in slot 1,
check the ATTACH LED display on the management module or enter the
show
attach
command.
The ATTACH LED is lit whenever there is a module
installed in slot 1.
Table 3-5.
Configuring Modules
Attachment
Additional
Attachment
Port
Equipment
Module
Type
Configuration
Required
Fiber
Dual
B/A
None
Dual homing
B/A
None
Single
S/M
None
Null
M/M
None
STP
Dual
B/A
2 Cascade connectors
Dual homing
B/A
2 Cascade connectors
Single
S/M
1 Cascade connector
Null
M/M
None
(continued)