For example
UPC - 662705029917
View all 3Com 3C780 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
Configuring the Hub 3-17 Table 3-5. Configuring Modules (continued) Module Attachment Type Attachment Additional Port Equipment Configuration Required UTP Dual B/A Dual homing B/A Cross-over cable Cross-over cable Single S/M Cross-over cable Null M/M Cross-over cable To change the configuration of the attachment ports, follow these steps: 1. Enter the set attach command. Type: set attach This selection prompt appears: Select one of the following: 1. B/A 2. S/M 3. M/M Attachment port configuration? 2. Select the attachment port configuration that you want. For example, type: 2 [Enter] These confirmation lines appear: Current configuration: B/A Initialize attachment as: S/M When you reset the hub, the attachment ports will be configured as S/M.