Dinion2X IP Camera 9.9 Interfaces Interfaces > Alarm input > Relay > COM1 Advanced Mode | en 101 9.9.1 9.9.2 Alarm input Configure the alarm triggers for the camera. Select N.C. (Normally Closed) if the alarm is to be triggered by closing the contact. Select N.O. (Normally Open) if the alarm is to be triggered by opening the contact. Name Enter a name for the alarm input. This is then displayed below the icon for the alarm input on the LIVEPAGE (if configured). Action Select the camera mode to switch to when alarm input 1 is triggered. See Section 9.8.8 Alarm Task Editor, page 100, for information on alarm actions based on alarm inputs. Relay Configure the switching behavior of the relay output. Select different events that automatically activate an output. For example, turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped. Idle state Select Open for the relay to operate as an N.O. contact, or select Closed if the relay is to operate as an N.C. contact. Select Select External device or Motion+/IVA to trigger the relay. Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06