Bosch NBN-498-11P Operation Manual - Page 29

Alarm and relay connector - - 28 v

Page 29 highlights

Dinion2X IP Camera 5.3 Alarm and relay connector Installation | en 29 Alarm 1 4 2 5 3 6 5 mm (0.2 in) Figure 5.3 Alarm and relay connector pins Pin Alarm socket 1 Alarm in 1 2 Alarm in 2 3 Relay out contact 1 4 Ground 5 Ground 6 Relay out contact 2 - Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation. - Alarm output relay switching capability: Max voltage 30VAC or +40 VDC. Max 0.5 A continuous, 10 VA. - Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled with 22 kOhm pull-up to +3.3 V. - Alarm in: configurable as active low or active high. - Max. 42 V allowed between camera ground and each of the relay pins. Use the alarm input to connect external alarm devices such as door contacts or sensors. A zero potential make-contact or switch can be used as the actuator (use a bounce-free contact system). Use the alarm relay output for switching external devices such as lamps or sirens. Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

Dinion2X IP Camera
Installation | en
29
Bosch Security Systems
Installation and Operation Manual
AR18-10-B006 | v1.1 | 2010.06
5.3
Alarm and relay connector
Figure 5.3
Alarm and relay connector pins
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
Alarm output relay switching capability: Max voltage 30VAC
or +40 VDC. Max 0.5 A continuous, 10 VA.
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled
with 22 kOhm pull-up to +3.3 V.
Alarm in: configurable as active low or active high.
Max. 42 V allowed between camera ground and each of the
relay pins.
Use the alarm input to connect external alarm devices such as
door contacts or sensors. A zero potential make-contact or
switch can be used as the actuator (use a bounce-free contact
system).
Use the alarm relay output for switching external devices such
as lamps or sirens.
Pin
Alarm socket
1
Alarm in 1
2
Alarm in 2
3
Relay out contact 1
4
Ground
5
Ground
6
Relay out contact 2
Alarm
1
2
3
4
5
6
5 mm
(0.2 in)