Cleaning the Electrical Terminals
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 202 highlights
MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN SERVICE MANUAL 4) Gently wipe the scanner window with a soft dry cloth. Fig. 5-40 5) Re-install the drum unit assembly into the machine. Close the front cover. 6) Plug in the power cord, and then turn on the power switch. ! CAUTION: • Handle the drum unit carefully since it contains toner. If toner scatters and your hands or cloths get dirty, immediately wipe or wash it off with cold water. • Do not touch the scanner window with your fingers. • Do not wipe the scanner window with isopropyl alcohol. 3.6 Cleaning the Electrical Terminals To obtain the best print performance, be sure to clean the electrical terminals inside the machine. 1) Turn off the power switch and unplug the power cord. 2) Remove the drum unit from the machine. 3) Wipe the electrical terminals as shown in the figure below with a soft dry cloth. Fig. 5-41 5-23