Brother International DCP 8040 Service Manual - Page 303
Selectors 2 through 4, 6 and 7 are not applicable where no PABX is installed.
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 303 highlights
APPENDIX 3 FIRMWARE SWITCHS (WSW) WSW03 (PABX* mode setting) Selector No. 1 2 | 4 5 6 | 8 Function CNG detection when sharing a modular wall socket with a telephone Not used. CNG detection when sharing a modular wall socket with a telephone Not used. Setting and Specifications 0: A 1: B 0: A 1: B * PABX: Private automatic branch exchange NOTE: Selectors 2 through 4, 6 and 7 are not applicable where no PABX is installed. l Selectors 1 and 5: CNG detection when sharing a modular wall socket with a telephone These selectors determine whether or not the machine detects a CNG signal when a line is connected to a telephone sharing a modular wall socket with the machine. Upon detection of CNG signals by the number of cycles specified by these selectors, the machine interprets CNG as an effective signal and then starts FAX reception. Selector No. 1 No. 5 0 (A) 0 (A) 1 (B) 1 (B) 0 (A) 1 (B) 0 (A) 1 (B) Cycle 0.5 cycle 1.0 cycle 1.5 cycles 2.0 cycles WSW04 (TRANSFER facility setting) Selector No. 1 | 6 Function Not used. 7 Break time length for flash function 8 Setting and Specifications No. 7 8 0 0 0 1 1 0 1 1 : 80 ms : 110 ms : 250 ms : 500 ms NOTE: Selectors 5 through 8 are not applicable in those countries where no transfer facility is supported. l Selectors 7 and 8: Break time length for flash function These selectors set the break time length. This setting is effective only when the flash function is selected for the R key by using the function switch. A-10