Brother International DCP 8040 Service Manual - Page 286
CCD Scanner Area Setting Maintenance mode 55
![]() |
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 286 highlights
CHAPTER 7 MAINTENANCE MODE 3.12 CCD Scanner Area Setting (Maintenance mode 55) < Function > The machine sets the CCD scanner area and stores it into the EEPROM. < Operating Procedure > (1) Press the 5 key twice in the initial stage of the maintenance mode. The "SCANNER AREA SET" will appear on the LCD. (2) When setting of the scanner area is completed, a 4-digit number will appear on the LCD. (e.g., 4723?) * If you press the Stop button at this point, the machine will return to the maintenance initial stage of the maintenance mode. Based on this 4-digit number and referring to the input data specified in the table, input its corresponding 5-digit data value (input data). (e.g., 4723? 47247) (3) Save the magnification compensation setting value in the EEPROM, and then return to the initial stage of the maintenance mode. < Input Data for Magnification Compensation after Performing Maintenance 55 > Maintenance 55 Required Input Data 1 4610 4619 2 4620 4629 3 4630 4639 4 4640 4649 5 4650 4659 6 4660 4669 7 4670 4679 8 4680 4689 9 4690 4699 10 4700 4709 11 4710 4719 12 4720 4729 13 4730 4739 14 4740 4749 15 4750 4759 16 4760 4769 17 4770 4779 18 4780 4789 19 4790 4799 20 4800 4809 21 4810 4819 22 4820 4829 23 4830 4839 Input data 46156 46257 46358 46459 46550 46651 46752 46853 46954 47056 47157 47247 47359 47450 47551 47652 47753 47854 47955 48057 48158 48259 48350 7-20
![](/manual_guide/products/brother-international-dcp-8040-service-manual-cb3132a/286.png)