Brother International DCP 8040 Service Manual - Page 312
Detecting time setting
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 312 highlights
MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN SERVICE MANUAL Selector No. 1 2 3 4 5 6 7 8 WSW12 (Signal detection condition setting) Function Min. OFF time length of calling signal (Ci) Max. OFF time length of calling signal (Ci) Detecting time setting Not used. Not used. No. 1 0 0 1 1 No. 3 0 0 1 1 No. 5 0 0 1 1 Setting and Specifications 2 0 : 1500 ms 1 : 500 ms 0 : 700 ms 1 : 900 ms 4 0 : 6 sec. 1 : 7 sec. 0 : 9 sec. 1 : 11 sec. 6 0 : 800 ms 1 : 200 ms 0 : 250 ms 1 : 150 ms l Selectors 1 through 4: Min. and max. OFF time length of calling signal (Ci) If the machine detects the OFF state of calling signal (Ci) for a time length which is greater than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the Ci signal as OFF. l Selectors 5 and 6: Detecting time setting These selectors set the time length required to make the machine acknowledge itself to be called. That is, if the machine continuously detects calling signals with the frequency set by selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it acknowledges the call. A-19