Brother International DCP 8040 Service Manual - Page 315
Selectors 8: CRP option
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 315 highlights
APPENDIX 3 FIRMWARE SWITCHS (WSW) Selector No. 1 2 3 | 6 7 8 WSW15 (REDIAL facility setting) Function Selection of redial interval No. of redialings Redialing for no response sent from the called terminal CRP option Setting and Specifications No. 1 0 0 1 1 No. 3 0 0 0 0 1 2 0 : 1 : 0 : 1 : 4 5 0 0 0 0 0 1 0 1 | 1 1 5 minutes 1 minute 2 minutes 3 minutes 6 0 : 16 times 1 : 1 times 0 : 2 times 1 : 3 times | 1 : 15 times 0: Redialing 1: No redialing 0: Disable 1: Enable l Selectors 1 through 6: Selection of redial interval and No. of redialings The machine redials by the number of times set by selectors 3 through 6 at intervals set by selectors 1 and 2. This setting is effective only when selector 7 is set to "0." l Selectors 7: Redialing for no response sent from the called terminal This selector determines whether or not the machine redials if no G3 command response comes from the called station after dialing within the time length set by selectors 7 and 8 of WSW09. l Selectors 8: CRP option If a command error occurs in the equipment (calling station), the equipment usually waits for three seconds and then makes a retry three times. This CRP option is a request command that can be sent from the called station for requesting the calling station to retry the failed command immediately. A-22