Brother International DCP 8040 Service Manual - Page 308
starts dialing.
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 308 highlights
MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN SERVICE MANUAL WSW08 (Dial tone setting 2) Selector No. Function 1 | 1st dial tone detection time 3 length 4 Time-out length for 1st and 2nd dial tone detection 5 6 Detection level of 1st dial tone | and busy tone before dialing 8 Setting and Specifications No. 1 2 3 0 0 0 : 0 0 1 : 0 1 0 : 0 1 1 : 1 0 0 : 1 0 1 : 1 1 0 : 1 1 1 : 50 ms 210 ms 500 ms 800 ms 900 ms 1.5 sec. 2.0 sec. 2.5 sec. No. 4 5 0 0 : 10 sec. 0 1 : 20 sec. 1 0 : 15 sec. 1 1 : 30 sec. No. 6 7 8 0 0 0 : -21 dBm 0 0 1 : -24 dBm 0 1 0 : -27 dBm 0 1 1 : -30 dBm 1 0 0 : -33 dBm 1 0 1 : -36 dBm 1 1 0 : -39 dBm 1 1 1 : -42 dBm NOTE: The WSW08 is not applicable in those countries where no dial tone detection is supported, e.g., U.S.A. l Selectors 1 through 3: 1st dial tone detection time length Upon detection of the 1st dial tone for the time length set by these selectors, the machine starts dialing. This setting is effective only when selectors 1 through 3 of WSW05 are set to "1,1,1." l Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection These selectors set the time-out length for the 1st and 2nd dial tone detection so that the machine waits dial tone input for the specified time length and disconnects itself from the line when no dial tone is inputted. A-15