Brother International DCP 8040 Service Manual - Page 336
If these selectors are set to 1, 1, 1, the fluorescent lamp will go off after the scanning
UPC - 012502610328
View all Brother International DCP 8040 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 336 highlights
MFC-8440/8840D/8840DN, DCP-8040/8045D/8045DN SERVICE MANUAL WSW41 (Function setting 19) Selector No. Function 1 | 3 ON-duration of the fluorescent lamp built in the CCD unit 4 Broadcast report via e-mail 5 Modem attenuator | 8 Setting and Specifications No. 1 2 3 0 0 0 : 16 hours 0 0 1 : 24 hours 0 1 0 : 12 hours 0 1 1 : 8 hours 1 0 0 : 4 hours 1 0 1 : 2 hours 1 1 0 : 10 minutes 1 1 1 : 0 minute 0: ON 1: OFF No. 5 6 7 8 0 0 0 0 : 0 0 0 1 : 0 0 1 0 : 0 0 1 1 : 0 1 0 0 : | 1 1 1 1 : -10 dBm -11 dBm -12 dBm -13 dBm -14 dBm | -25 dBm NOTE: • WSW41 takes effect only in the V. 34 mode. • Selectors 1 through 3 are applicable only to models equipped with a flat-bed scanner. l Selectors 1 through 3: ON-duration of the fluorescent lamp built in the CCD unit If the scanning operation is started when the fluorescent lamp is off, then the lamp will come on for scanning. These selectors determine how long the lamp will stay ON after scanning. If these selectors are set to "1, 1, 1," the fluorescent lamp will go off after the scanning sequence. l Selectors 5 through 8: Modem attenuator These selectors are used to adjust the transmitting level of the modem when the reception level at the remote station is improper due to line loss. This function applies to super G3 protocol signals. A-43