Brother International TD-4750TNWB Users Guide - Page 68
Problem, Possible Cause, Solution, For more information about cleaning the printer, see
![]() |
View all Brother International TD-4750TNWB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
Problem The printing position of small labels is incorrect. Possible Cause The media sensor sensitivity is not set correctly. The label size is incorrect. The vertical offset setting in the driver is incorrect. Solution Calibrate the sensor sensitivity again. Set the correct label size and gap size. If using the BarTender software, set the Vertical Offset in the driver. Incomplete printing on the left or right side of label. Warped labels. The label size is set up incorrectly. The ribbon is installed incorrectly. The media is installed incorrectly. Blank labels with gray lines. The print density setting is incorrect. The media is not fed correctly. The Print Head is dirty. The Platen Roller is dirty. Irregular printing. The printer is in Hex Dump mode. Set the correct label size. Reinstall the ribbon. To install the ribbon roll, see section 3.1 Load the Ribbon. Reinstall the label roll. To install the label roll, see section 3.2 Load the Media. Adjust the print density to improve the print quality. Make sure the label guide touches the edge of the Media Guide Tips. Clean the Print Head. Clean the Platen Roller. Turn the printer on and off to skip the dump mode. (See section 5.1.2 Gap/Black Mark Sensor Calibration, Self-Test, and Entering Dump Mode.) For more information about cleaning the printer, see section 11. Maintenance. 64