Dell PowerEdge 1955 Configuration Guide - Page 28

console&gt, consoleconfig, admin, secret

Page 28 highlights

NOTE: A Gb Ethernet pass-through module is also available as an option and requires no configuration. The Gb Ethernet pass-through module must be connected to a 1000 Mb port on the external switch (10 Mb and 100 Mb ports are not supported). Before configuring the switch, obtain the following information from your network administrator: • Username and password • The IP address to be assigned to the VLAN 1 interface through which the device is to be managed • The IP subnet mask for the network • The IP address of the default gateway To configure the PowerConnect 5316M Ethernet switch module using the internal serial port on the DRAC/MC module, perform the following steps: 1 Log on to the DRAC/MC Telnet or serial interface. 2 To redirect the switch console through the DRAC/MC console, enter the following command: connect switch-x where x is the module slot number on the chassis. For example, if you are connecting to switch module 1, type connect switch-1 3 Enter the following commands to enter and change to global configuration mode: console> enable console# configure console(config)# 4 Set the user name and password with the highest privilege level of 15 with the following command: console(config)# username admin password secret level 15 NOTE: The username "admin" and password "secret" are used only for example-those fields are user-selectable. 5 Configure the static address to be assigned to the VLAN interface as 192.168.1.123 (example only) and subnet mask of 255.255.255.0 (example only) with the following commands: console(config)# interface vlan 1 console(config-if)# ip address 192.168.1.123 255.255.255.0 6 Configure the IP default gateway as 192.168.1.1(example only) with the following commands: console(config-if)# exit console(config)# ip default-gateway 192.168.1.1 26 General System Configuration

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206

26
General System Configuration
NOTE:
A Gb Ethernet pass-through module is also available as an option and requires no configuration.
The Gb Ethernet pass-through module must be connected to a 1000 Mb port on the external switch
(10 Mb and 100 Mb ports are not supported).
Before configuring the switch, obtain the following information from your network administrator:
Username and password
The IP address to be assigned to the VLAN 1 interface through which the device is to be
managed
The IP subnet mask for the network
The IP address of the default gateway
To configure the PowerConnect 5316M Ethernet switch module using the internal serial port on
the DRAC/MC module, perform the following steps:
1
Log on to the DRAC/MC Telnet or serial interface.
2
To redirect the switch console through the DRAC/MC console, enter the following command:
connect
switch-
x
where
x
is the module slot number on the chassis. For example, if you are connecting to
switch module 1, type
connect
switch-1
3
Enter the following commands to enter and change to global configuration mode:
console>
enable
console#
configure
console(config)#
4
Set the user name and password with the highest privilege level of 15 with the following
command:
console(config)#
username
admin
password
secret
level
15
NOTE:
The username "admin" and password "secret" are used only for example—those fields are
user-selectable.
5
Configure the static address to be assigned to the VLAN interface as 192.168.1.123 (example
only) and subnet mask of 255.255.255.0 (example only) with the following commands:
console(config)#
interface
vlan
1
console(config-if)#
ip address
192.168.1.123 255.255.255.0
6
Configure the IP default gateway as 192.168.1.1(example only) with the following commands:
console(config-if)#
exit
console(config)#
ip default-gateway
192.168.1.1