Table 10. Configuration 2: R1a+R2b continued, Table 11. Configuration 3: R1b, Card type, Slot priority

Page 35 highlights

Table 10. Configuration 2: R1a+R2b (continued) Card type Slot priority Intel (NIC: 25Gb) 1, 2 Mellanox (NIC: 25Gb) 1, 2 SolarFlare (NIC: 25Gb) 1, 2 Mellanox (NIC: HDR100 VPI) 1, 2 Mellanox (NIC: HDR VPI) 1, 2 Intel (OCP: 100Gb) Integrated slot Broadcom (OCP: 25Gb) Integrated slot Intel (OCP: 25Gb) Integrated slot Marvell (OCP: 25Gb) Integrated slot Mellanox (OCP: 25Gb) Integrated slot QLogic (OCP: 25Gb) Integrated slot Broadcom (OCP: 10Gb) Integrated slot QLogic (OCP: 10Gb) Integrated slot Intel (OCP: 10Gb) Integrated slot Broadcom (OCP: 1Gb) Integrated slot Intel (OCP: 1Gb) Integrated slot Dell External PERC Adapter 1 Dell BOSS M.2 Module Integrated slot Intel (PCIe SSD AIC) 1 Samsung (PCIe SSD AIC) 1 Nvidia (GPU: T4 16 GB) 2 Table 11. Configuration 3: R1b Card type Mellanox (NIC: 100Gb) Mellanox (NIC: HDR100 VPI) Mellanox (NIC: HDR VPI) Intel (OCP: 100Gb) Broadcom (OCP: 25Gb) Intel (OCP: 25Gb) Marvell (OCP: 25Gb) Mellanox (OCP: 25Gb) QLogic (OCP: 25Gb) Broadcom (OCP: 10Gb) QLogic (OCP: 10Gb) Intel (OCP: 10Gb) Broadcom (OCP: 1Gb) Intel (OCP: 1Gb) Slot priority 1 1 1 Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Integrated slot Maximum number of cards 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Maximum number of cards 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Installing and removing system components 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

Table 10. Configuration 2: R1a+R2b (continued)
Card type
Slot priority
Maximum number of cards
Intel (NIC: 25Gb)
1, 2
2
Mellanox (NIC: 25Gb)
1, 2
2
SolarFlare (NIC: 25Gb)
1, 2
2
Mellanox (NIC: HDR100 VPI)
1, 2
2
Mellanox (NIC: HDR VPI)
1, 2
2
Intel (OCP: 100Gb)
Integrated slot
1
Broadcom (OCP: 25Gb)
Integrated slot
1
Intel (OCP: 25Gb)
Integrated slot
1
Marvell (OCP: 25Gb)
Integrated slot
1
Mellanox (OCP: 25Gb)
Integrated slot
1
QLogic (OCP: 25Gb)
Integrated slot
1
Broadcom (OCP: 10Gb)
Integrated slot
1
QLogic (OCP: 10Gb)
Integrated slot
1
Intel (OCP: 10Gb)
Integrated slot
1
Broadcom (OCP: 1Gb)
Integrated slot
1
Intel (OCP: 1Gb)
Integrated slot
1
Dell External PERC Adapter
1
1
Dell BOSS M.2 Module
Integrated slot
1
Intel (PCIe SSD AIC)
1
1
Samsung (PCIe SSD AIC)
1
1
Nvidia (GPU: T4 16 GB)
2
1
Table 11. Configuration 3: R1b
Card type
Slot priority
Maximum number of cards
Mellanox (NIC: 100Gb)
1
1
Mellanox (NIC: HDR100 VPI)
1
1
Mellanox (NIC: HDR VPI)
1
1
Intel (OCP: 100Gb)
Integrated slot
1
Broadcom (OCP: 25Gb)
Integrated slot
1
Intel (OCP: 25Gb)
Integrated slot
1
Marvell (OCP: 25Gb)
Integrated slot
1
Mellanox (OCP: 25Gb)
Integrated slot
1
QLogic (OCP: 25Gb)
Integrated slot
1
Broadcom (OCP: 10Gb)
Integrated slot
1
QLogic (OCP: 10Gb)
Integrated slot
1
Intel (OCP: 10Gb)
Integrated slot
1
Broadcom (OCP: 1Gb)
Integrated slot
1
Intel (OCP: 1Gb)
Integrated slot
1
Installing and removing system components