Epson FX 1170 Service Manual - Page 35

Printer Initialization, The READY LED lights.

Page 35 highlights

REV.-A Position 1 (3rd step) &'"$\\ -=. . . r' Platen Gap Adjust Lever 4.- Q Figure 1-10. Lever Positions 1.5.12 Printer Initialization The printer is initialized in the following cases. (1) When the printer is turned on. (2) When the INIT signal or CMREQ (optional l/F ) is input. When the printer is initialized, it performs the following functions: q The printhead returns to the leftmost position (carriage home). q The READY LED lights. q The printer clears the print buffer and input data buffer. q The line spacing is set to 1/6 inch. q The page length and skip over perforation settings are returned to their default values. q All vertical tab positions are cleared. q The horizontal tab positions are set to every 8 columns. q The print mode is set to the default value set from the control paneI and stored in non-volatile memory. TOF position will be reset in the following cases. (1) Power on (2) INIT signal or CMREQ (optional I/F) (3) Sofiware reSet command (ESC @) (4) Page length command (ESC C) NOTE: The CMREQ signal goes Low when the command request is sent from the optional card to the main system. 1-26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

REV.-A
Position 1
(3rd step)
$
\
\
.
.
-=.
&’”
r’
Platen Gap Adjust Lever
Q
Figure 1-10. Lever Positions
1.5.12 Printer Initialization
The printer is initialized in the following cases.
(1) When the printer is turned on.
(2) When the
INIT
signal
or
CMREQ
(optional l/F ) is input.
When the printer is initialized, it performs the following functions:
The printhead returns to the leftmost position (carriage home).
The READY LED lights.
The printer clears the print buffer and input data buffer.
The line spacing is set to 1/6 inch.
The page length and skip over perforation settings are returned to their default values.
All vertical tab positions are cleared.
The horizontal tab positions are set to every 8 columns.
The print mode is set to the default value set from the control paneI and stored in non-volatile memory.
TOF position will be reset in the following cases.
(1) Power on
(2)
INIT
signal or
CMREQ
(optional I/F)
(3)
Sofiware
reSet command
(ESC
@)
(4) Page length command
(ESC
C)
4.-
NOTE: The
CMREQ
signal goes
Low
when the
command
request
is
sent
from
the
optional
card
to
the main
system.
1-26