HP Disk System 2300 HP StorageWorks Disk System 2300 User's Guide(This manual - Page 105
Problem, Description, HW Event, Category, State, Status, Probable Cause/Solution
View all HP Disk System 2300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
Table 12. Troubleshooting Table (Continued) Problem HW Event LED Description Category State STM Status Probable Cause/Solution Power supply/ Critical fan LED is amber Amber Critical An incompatible or defective component caused a temporary fault. Power supply hardware is faulty. Unplug the power cord and wait for the LED to turn off. Reinsert the power cord. If fault persists, replace the power supply. IOSCAN lists BCC and disks as NO_HW Critical All normal none SCSI cable is unplugged or loose at either end. SCSI cable is damaged. Replace with another cable to test. HBA is faulty. Check status and correct any problem. All off none Disk system is powered off. Enclosure Monitor Switch is set on SAF-TE mode. IOSCAN lists none disk as NO_HW On or off (See STM Disk is faulty. Replace. Disk Tool) midplane is faulty. Replace. Troubleshooting Troubleshooting 105