Table 12. Troubleshooting Table (Continued) Problem HW Event LED Description Category State STM Status Probable Cause/Solution Temperatur Critical e is over limit none Critical Temp is >54.5º C Major none Warning Noncritical Temp is >36º C Temperature sensors are on the BCC and are independent of power supplies. Investigate temperature warnings immediately, before power supplies sense critical temperature and turn off. A fan is faulty. Check status and correct. Airflow is obstructed; vents are blocked. One or more slots are empty. Power supply is faulty. Check status and correct. Room temperature is too high. If ambient temperature cannot be reduced in a reasonable time, turn off product to prevent shortened life. Temperature sensor is faulty. Compare temperature reported by peer BCC. Temperature Critical is under limit none Major none Warning Critical Temps