HP Disk System 2300 HP StorageWorks Disk System 2300 User's Guide(This manual - Page 23
replacement fan module/power supply is not available, leave the failed power
View all HP Disk System 2300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Product Description Power supplies share the load reciprocally; that is, each supply automatically increases its output to compensate for reduced output from the other, and vice versa. If one power supply fails, the other delivers the entire load. Internal circuitry triggers a fault when the internal fan or other part fails. At the same time, the power fault LED (amber) illuminates, and, if enabled, the hardware event monitor sends an event message. The power supply fan remains on if other parts fail in order to maintain cooling air flow through the system. If the fan fails, the power supply shuts down. The fan in the other working power supply will increase to full speed to compensate for the failed fan. The failed power supply/fan module must be removed and the replacement power supply/ fan module installed within two minutes. In the event of a failure, if a replacement fan module/power supply is not available, leave the failed power supply/fan module installed until you are ready to replace it. This should be done to maintain proper cooling for the disk system. Internal circuitry senses fan motion and triggers a fault when the speed of the power supply's internal fan falls below a critical level. At the same time, the LED turns amber, and, if enabled, the hardware event monitor sends an event message. Product Description 23