Enable Restrict Reassign to One Block

Page 59 highlights

Chapter 4 Configuration • Enable SAF-TE Use of UPS - Enables monitoring of uninterruptable power supply (if supported by the system enclosure). This is not currently supported by the HP Rack Storage/12FC. • Enable Restrict Reassign to One Block - Restricts a reassign to the failing block. If disabled, reassigns will be for the entire current I/O blocks, not just all of the failing blocks. • Enable Smart Large Host Transfers - For transfers larger than the stripe size, allows selection of Coalesce (fewer disconnects) on host data transfers. • Enable Elevator Ordering of Device Queues - Attempts to keep the drive heads moving in the same direction as long as possible to improve performance. Assumes LBAs are physically sequentially ordered. • Enable Coalesce Device Queues - Joins data from adjacent I/Os into a single I/O to improve performance. • Enable Super Read Ahead (SRA) - Extends the Read Ahead process by always reading an extra cache line on a read request and reading an additional cache line when a cache hit occurs. Most useful for applications where read-sequential data is high. • Enable True Verification of Data - Performs a true verify with data comparison. • Enable Write Through Verify - During error handling, this turns on Force Unit Access for reads and writes. • Enable Operational Fault Management - Allows the controller to take autonomous actions when a failure occurs. Do not disable this function unless specifically instructed to do so as part of a troubleshooting diagnostic activity. Disable (by checking) or Enable (by un-checking) the following option: • Disable Wide Transfer on Host - When disabled, the controller will negotiate only narrow data transfers. Doing this unnecessarily will result in slower performance. 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

Chapter 4
Configuration
53
Enable SAF-TE Use of UPS
- Enables monitoring of uninterruptable
power supply (if supported by the system enclosure). This is not currently
supported by the HP Rack Storage/12FC.
Enable Restrict Reassign to One Block
- Restricts a reassign to the
failing block. If disabled, reassigns will be for the entire current I/O blocks,
not just all of the failing blocks.
Enable Smart Large Host Transfers
- For transfers larger than the stripe
size, allows selection of Coalesce (fewer disconnects) on host data
transfers.
Enable Elevator Ordering of Device Queues
- Attempts to keep the drive
heads moving in the same direction as long as possible to improve
performance. Assumes LBAs are physically sequentially ordered.
Enable Coalesce Device Queues
- Joins data from adjacent I/Os into a
single I/O to improve performance.
Enable Super Read Ahead (SRA)
- Extends the Read Ahead process by
always reading an extra cache line on a read request and reading an
additional cache line when a cache hit occurs. Most useful for applications
where read-sequential data is high.
Enable True Verification of Data
- Performs a true verify with data
comparison.
Enable Write Through Verify
- During error handling, this turns on
Force Unit Access for reads and writes.
Enable Operational Fault Management
- Allows the controller to take
autonomous actions when a failure occurs. Do not disable this function
unless specifically instructed to do so as part of a troubleshooting
diagnostic activity.
Disable (by checking) or Enable (by un-checking) the following option:
Disable Wide Transfer on Host
- When disabled, the controller will
negotiate only narrow data transfers. Doing this unnecessarily will result in
slower performance.