Chapter 2 Remove two screws securing NetServer to rack Cover 1 Installation Remove two screws securing NetServer to rack Do not remove three screws securing the bezel hinge to the NetServer Cover 3 Cover 2 Do not remove two screws securing the bezel latch to the NetServer Figure 2-5. Front Bezel Screw Locations for HP Rack 6. Pull the NetServer forward from the rack until the lockout device engages with a click. For a NetServer in a Compaq Rack For an HP NetServer in a Compaq rack, refer to the NetServer documentation and your rack documentation for instructions as you do the following to remove the front bezel: 1. Verify that the anti-tip feature is installed on the rack and that the leveler feet are lowered. WARNING To prevent the rack from tipping over, ensure that the anti-tip feature is installed before extending the NetServer from the rack. Also lower the leveler feet of the rack to improve stability and to prevent the rack from rolling. Do NOT extend more than one piece of equipment at a time out from the front of the rack. Failure to take these precautions could result in serious injury and equipment damage. 2. If there is a door on the rack, remove it. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Chapter 2
Installation
13
Remove two
screws securing
NetServer to rack
Do not
remove three
screws securing the
bezel hinge to the
NetServer
Remove two
screws securing
NetServer to rack
Do not
remove
two screws
securing the
bezel latch to
the NetServer
Cover 3
Cover 1
Cover 2
Figure 2-5. Front Bezel Screw Locations for HP Rack
6.
Pull the NetServer forward from the rack until the lockout device engages
with a click.
For a NetServer in a Compaq Rack
For an HP NetServer in a Compaq rack, refer to the NetServer documentation and
your rack documentation for instructions as you do the following to remove the
front bezel:
1.
Verify that the anti-tip feature is installed on the rack and that the leveler
feet are lowered.
WARNING
To prevent the rack from tipping over, ensure that the anti-tip
feature is installed before extending the NetServer from the
rack. Also lower the leveler feet of the rack to improve
stability and to prevent the rack from rolling. Do NOT extend
more than one piece of equipment at a time out from the front
of the rack. Failure to take these precautions could result in
serious injury and equipment damage.
2.
If there is a door on the rack, remove it.