HP LH4r HP Netserver LH 3/r and LH 4/r Mass Storage Kit - Page 55

Order, Bus DevFunc, SYM53C895 01, Press any key

Page 55 highlights

Chapter 3 Configure Mass Storage 6. The Adapter Boot Order screen displays the two SCSI controllers and numbers representing their boot order in the following form: Boot Order Boot Bus DevFunc Order Bus DevFunc A SYM53C895 01 30 B SYM53C895 01 38 where A and B are the numbers 0 or 1 or a blank. The number in the A position indicates the boot order of the SCSI A controller, and the number in the B position indicates the boot order of the SCSI B controller. ◊ 0 marks the controller of the SCSI channel searched first for a bootable drive. ◊ 1 marks the controller of the SCSI channel searched second for a bootable drive. ◊ A blank indicates that the controller's SCSI channel is not searched for a bootable drive. To add or change a boot order sequence number, use the right and left arrow keys to highlight the controller, and then press ENTER. Type the new sequence number (0 or 1), and press ENTER. The boot order sequence number of the other controller will change, if necessary. 0 must be assigned to a controller before 1 can be assigned to the other controller. To remove a controller from the boot order, use the right and left arrow keys to highlight the controller, and then press ENTER twice. (This creates a blank.) The boot order sequence number of the other controller will change to 0, if necessary. 7. Press ESC to return to the Main Menu. To begin to exit the utility, use the up and down arrow keys to highlight Quit, and press ENTER. When the message Rebooting system to change global settings... Press any key is displayed, press any key to exit the Symbios Configuration utility and restart the NetServer. 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Chapter 3
Configure Mass Storage
51
6.
The Adapter Boot Order screen displays the two SCSI controllers and
numbers representing their boot order in the following form:
Boot
Boot
Order
Bus DevFunc
Order
Bus DevFunc
A
SYM53C895 01
30
B
SYM53C895 01
38
where
A
and
B
are the numbers 0 or 1 or a blank.
The number in the
A
position indicates the boot order of the SCSI A
controller, and the number in the
B
position indicates the boot order of the
SCSI B controller.
0 marks the controller of the SCSI channel searched first for a bootable
drive.
1 marks the controller of the SCSI channel searched second for a
bootable drive.
A blank indicates that the controller’s SCSI channel is not searched for
a bootable drive.
To add or change
a boot order sequence number, use the right and left
arrow keys to highlight the controller, and then press ENTER. Type the
new sequence number (0 or 1), and press ENTER. The boot order sequence
number of the other controller will change, if necessary. 0 must be assigned
to a controller before 1 can be assigned to the other controller.
To remove
a controller from the boot order, use the right and left arrow
keys to highlight the controller, and then press ENTER twice. (This creates
a blank.) The boot order sequence number of the other controller will
change to 0, if necessary.
7.
Press ESC to return to the Main Menu. To begin to exit the utility, use the
up and down arrow keys to highlight
Quit
, and press ENTER. When the
message
Rebooting system to change global settings...
Press any key
is displayed, press any key to exit the Symbios Configuration utility and
restart the NetServer.