HP LH4r HP Netserver LH 3/r and LH 4/r Mass Storage Kit - Page 24

flanges are flush with the NetServer chassis front.

Page 24 highlights

Chapter 2 Installation CAUTION As you insert the cage, be careful not to damage the cage's backplane, management board, and the insulating sheet covering them (not shown in Figure 2-11). 2. Insert the hot-swap mass storage cage by sliding it carefully into the mass storage expansion bay, as shown in Figure 2-11. 3. When the cage is correctly positioned, press it firmly into place, so that its flanges are flush with the NetServer chassis front. 4. Using the two circular access holes in the NetServer chassis shown in Figure 2-12, insert and tighten two screws supplied with the upgrade kit. ◊ HP NetServer LH 3 or LH 4 access holes are on the side of the chassis. ◊ HP NetServer LH 3r or LH 4r access holes are on the top of the chassis. 1 Access Holes 2 1 2 Access Holes Pedestal Configuration Rack-Optimized Configuration Figure 2-12. Insert and Tighten Two Screws (1), and Then Insert and Tighten Six Screws (2); Shown for HP NetServer LH 3 and LH 3r 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Chapter 2
Installation
20
CAUTION
As you insert the cage, be careful not to damage the cage’s
backplane, management board, and the insulating sheet
covering them (not shown in Figure 2-11).
2.
Insert the hot-swap mass storage cage by sliding it carefully into the mass
storage expansion bay, as shown in Figure 2-11.
3.
When the cage is correctly positioned, press it firmly into place, so that its
flanges are flush with the NetServer chassis front.
4.
Using the two circular access holes in the NetServer chassis shown in
Figure 2-12, insert and tighten two screws supplied with the upgrade kit.
HP NetServer LH 3 or LH 4 access holes are on the side of the chassis.
HP NetServer LH 3r or LH 4r access holes are on the top of the chassis.
Access Holes
1
2
2
1
Access Holes
Pedestal Configuration
Rack-Optimized Configuration
Figure 2-12. Insert and Tighten Two Screws (1), and Then Insert and Tighten
Six Screws (2); Shown for HP NetServer LH 3 and LH 3r