HP LH4r Integrated HP NetRaid Controller Configuration Guide - Page 103

utility. See Step D. Enable Integrated HP NetRAID Controller in

Page 103 highlights

Chapter 9 Configuring a Second Integrated HP NetRAID Channel 7. Select the Configuration menu, and choose Clear Configuration. 8. Exit HP NetRAID Assistant and reboot the HP NetServer. 9. Enable HP NetRAID on the second SCSI channel using the Setup (F2) utility. See "Step D. Enable Integrated HP NetRAID Controller" in this guide for complete instructions. ◊ Integrated HP NetRAID should be set to Enable. ◊ Included SCSI_A Channel should be set to Yes. ◊ Included SCSI_B Channel should be set to Yes. 10. Verify that your hardware is set up correctly for your second channel. The second channel may use hot-swap disk drive modules in a second hotswap mass storage cage or in an external mass storage enclosure. Make sure that the SCSI IDs of the non-hot-swap devices do not conflict with the SCSI IDs of the hot-swap disk drive modules connected to SCSI B. 11. Boot the HP NetServer Navigator CD-ROM and launch HP NetRAID Assistant as described in "Step E" in Chapter 5 of this guide. 12. Select the Configuration menu, and then choose Wizard. 13. Choose Custom mode and define arrays, hot spares, and logical drives on both of your channels. Configure your system exactly as defined in the two sets of worksheets you prepared in Steps 3 and 4. For complete instructions on configuring arrays and logical drives, see "Step F" in Chapter 5 of this guide. 14. Save your configuration and initialize your logical drives as described in "Step G" in Chapter 5 of this guide. Exit HP NetRAID Assistant. 15. Reinstall your NOS, HP NetRAID drivers, and HP NetRAID utilities as described in Chapter 6 of this guide. These files are installed on Logical Drive 0. 16. Set your SCSI Transfer Rate if necessary, as described in "Step L" in Chapter 6 of this guide. 17. Prepare your new logical drives for online capacity expansion if desired, as described in Chapter 7 of this guide. 18. Restore your data onto your new logical drives. Your configuration for a two-channel HP NetRAID system is now complete. 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Chapter 9
Configuring a Second Integrated HP NetRAID Channel
97
7.
Select the
Configuration
menu, and choose
Clear Configuration
.
8.
Exit HP NetRAID Assistant and reboot the HP NetServer.
9.
Enable HP NetRAID on the second SCSI channel using the Setup (F2)
utility. See "Step D. Enable Integrated HP NetRAID Controller" in this
guide for complete instructions.
Integrated HP NetRAID
should be set to
Enable
.
Included SCSI_A Channel
should be set to
Yes
.
Included SCSI_B Channel
should be set to
Yes
.
10.
Verify that your hardware is set up correctly for your second channel. The
second channel may use hot-swap disk drive modules in a second hot-
swap mass storage cage or in an external mass storage enclosure. Make
sure that the SCSI IDs of the non-hot-swap devices do not conflict with
the SCSI IDs of the hot-swap disk drive modules connected to SCSI B.
11.
Boot the
HP NetServer Navigator CD-ROM
and launch HP NetRAID
Assistant as described in "Step E" in Chapter 5 of this guide.
12.
Select the
Configuration
menu, and then choose
Wizard
.
13.
Choose
Custom
mode and define arrays, hot spares, and logical drives on
both of your channels. Configure your system exactly as defined in the two
sets of worksheets you prepared in Steps 3 and 4.
For complete instructions on configuring arrays and logical drives, see
"Step F" in Chapter 5 of this guide.
14.
Save your configuration and initialize your logical drives as described in
"Step G" in Chapter 5 of this guide. Exit HP NetRAID Assistant.
15.
Reinstall your NOS, HP NetRAID drivers, and HP NetRAID utilities as
described in Chapter 6 of this guide. These files are installed on Logical
Drive 0.
16.
Set your SCSI Transfer Rate if necessary, as described in "Step L" in
Chapter 6 of this guide.
17.
Prepare your new logical drives for online capacity expansion if desired,
as described in Chapter 7 of this guide.
18.
Restore your data onto your new logical drives.
Your configuration for a two-channel HP NetRAID system is now complete.