HP LH4r Integrated HP NetRaid Controller Configuration Guide - Page 45
Configuration
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
5 Configuration Overview This chapter covers Steps C, D, E, F, and G of the installation procedure. You should already have completed Step A, "Plan Your Hardware," and Step B, "Plan Arrays and Logical Drives" in Chapter 4. Step C. Verify Hardware Setup Verify that your hardware setup matches the plans you sketched in Worksheet A. Make sure that: • Disk drive modules are inserted in the hot-swap mass storage cage • You have installed a second mass storage cage, or you have connected an external mass storage enclosure, if you are planning to use two channels • SCSI IDs are set NOTE Make sure the SCSI IDs of the non-hot-swap devices do not conflict with the SCSI IDs of the hot-swap disk drive modules connected to SCSI B. Step D. Enable Integrated HP NetRAID Controller The HP NetServer LH 3 and LH 3r factory default setting enables the integrated HP NetRAID controller for the SCSI A port only. Use the Setup utility to verify this setting, or to enable the integrated HP NetRAID controller for the SCSI B port as well. 39