HP LH4r Integrated HP NetRaid Controller Configuration Guide - Page 46

Press <F2> to enter SETUP, Integrated HP NetRAID [Enable/Disable], Included SCSI_A Channel [

Page 46 highlights

Chapter 5 Configuration CAUTION If you ever use the Setup (F2) utility to reset to system defaults, your HP NetRAID configuration will also be reset to its default value. The default HP NetRAID configuration enables integrated HP NetRAID and includes SCSI A only. If you have changed the HP NetRAID configuration in the Setup utility, and then you reset to system defaults, you must re-enable the correct HP NetRAID channels before you exit the Setup utility. 1. Turn on the power to the HP NetServer and display monitor. 2. Press the F2 function key when you see this message: Press to enter SETUP 3. If a password has been set, provide it when prompted. 4. When the Setup Utility menu is displayed, the settings for the integrated HP NetRAID controller are: • Integrated HP NetRAID [Enable/Disable] This setting enables or disables the integrated HP NetRAID controller for both SCSI ports. To use the HP NetRAID controller, this setting must be set to Enable. • Included SCSI_A Channel [Yes/No] If the integrated HP NetRAID controller is enabled, this setting selectively includes or excludes SCSI port A from the HP NetRAID subsystem. • Included SCSI_B Channel [Yes/No] If the integrated HP NetRAID controller is enabled, this setting selectively includes or excludes SCSI port B from the HP NetRAID system. NOTE If you enable HP NetRAID for just one SCSI channel, that becomes the integrated HP NetRAID Channel 0. If you enable both SCSI channels, SCSI A becomes Channel 0, and SCSI B becomes Channel 1. 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Chapter 5
Configuration
40
CAUTION
If you ever use the Setup (F2) utility to reset to system
defaults, your HP NetRAID configuration will also be reset to
its default value.
The default HP NetRAID configuration
enables integrated HP NetRAID and includes SCSI A only.
If you have changed the HP NetRAID configuration in the
Setup utility, and then you reset to system defaults, you must
re-enable the correct HP NetRAID channels before you exit
the Setup utility.
1.
Turn on the power to the HP NetServer and display monitor.
2.
Press the
F2
function key when you see this message:
Press <F2> to enter SETUP
3.
If a password has been set, provide it when prompted.
4.
When the Setup Utility menu is displayed, the settings for the integrated
HP NetRAID controller are:
Integrated HP NetRAID [Enable/Disable]
This setting enables or disables the integrated HP NetRAID controller
for both SCSI ports. To use the HP NetRAID controller, this setting
must be set to
Enable
.
Included SCSI_A Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this setting
selectively includes or excludes SCSI port A from the HP NetRAID
subsystem.
Included SCSI_B Channel [Yes/No]
If the integrated HP NetRAID controller is enabled, this setting
selectively includes or excludes SCSI port B from the HP NetRAID
system.
NOTE
If you enable HP NetRAID for just one SCSI channel, that
becomes the integrated HP NetRAID Channel 0. If you enable
both SCSI channels, SCSI A becomes Channel 0, and SCSI B
becomes Channel 1.