HP LH4r Integrated HP NetRaid Controller Configuration Guide - Page 97
Configuring a Second Integrated, HP NetRAID Channel
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
9 Configuring a Second Integrated HP NetRAID Channel If you have already configured, and are operating, a one-channel integrated HP NetRAID system, you can add a second HP NetRAID channel at any time. This chapter provides instructions on adding a second HP NetRAID channel after one channel has been operating for a time. (There are no special instructions if you enable two HP NetRAID channels when you first configure your system.) WARNING Be sure to follow these instructions exactly. If you don't follow all of the steps, you may jeopardize the integrity of your existing data. Be sure to back up your data--both RAID and non-RAID-before you configure a second integrated HP NetRAID channel. It is essential that you back up before you reconfigure your system. When you enable a second channel, you will have both Channel 0 and Channel 1. • If you initially included SCSI A on HP NetRAID, and now plan to include SCSI B, then the drives on SCSI A stay associated with HP NetRAID Channel 0, and the drives on SCSI B are now associated with HP NetRAID Channel 1. • If you initially included SCSI B on HP NetRAID, and now plan to include SCSI A, then the drives on SCSI B become HP NetRAID Channel 1, and the drives on SCSI A are now associated with HP NetRAID Channel 0. 91