HP LH4r Integrated HP NetRaid Controller Configuration Guide - Page 69

To change the SCSI transfer rate, Select Adapter, Objects, SCSI Channel, SCSI Transfer Rate, Ultra,

Page 69 highlights

Chapter 6 HP NetRAID Software To change the SCSI transfer rate: 1. If you have installed one or more HP NetRAID-3Si adapters, select the integrated controller or adapter controlling the SCSI channel on which Fast/Wide or Ultra SCSI support is to be enabled: ◊ Choose Select Adapter from the Tools Management menu. ◊ Select the adapter controlling the SCSI channel of interest. 2. Choose Objects from the Tools Management menu. 3. Choose SCSI Channel from the Objects menu. 4. Select the channel on which the SCSI transfer rate is to be changed. 5. To change the SCSI transfer rate: ◊ Choose SCSI Transfer Rate from the SCSI Channel menu. A submenu appears. ◊ Use the arrow keys to highlight your selection: Fast, Ultra, or Ultra2. Press Enter. ◊ Choose Yes to confirm your selection. 6. Press Esc to return to the Tools Management menu. Disable the HP NetRAID BIOS If you want to prevent the system from booting from the integrated HP NetRAID controller, you can disable the HP NetRAID BIOS. To disable the HP NetRAID BIOS: 1. If you have installed one or more HP NetRAID-3Si adapters, select the integrated controller or adapter on which you want to disable the BIOS. ◊ Choose Select Adapter from the Tools Management menu. ◊ Select the adapter for which you want to disable the BIOS. 2. Choose Disable BIOS from the Tools Management menu. Exit HP NetRAID Express Tools To exit HP NetRAID Express Tools, press Esc repeatedly until the Exit? prompt is displayed. Choose Yes. Then press any key to reboot. The new parameters become effective after you reboot. 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141

Chapter 6
HP NetRAID Software
63
To change the SCSI transfer rate:
1.
If you have installed one or more HP NetRAID-3Si adapters, select the
integrated controller or adapter controlling the SCSI channel on which
Fast/Wide or Ultra SCSI support is to be enabled:
Choose
Select Adapter
from the Tools Management menu.
Select the adapter controlling the SCSI channel of interest.
2.
Choose
Objects
from the Tools Management menu.
3.
Choose
SCSI Channel
from the Objects menu.
4.
Select the channel on which the SCSI transfer rate is to be changed.
5.
To change the SCSI transfer rate:
Choose
SCSI Transfer Rate
from the SCSI Channel menu. A
submenu appears.
Use the arrow keys to highlight your selection:
Fast
,
Ultra
, or
Ultra2
.
Press Enter.
Choose
Yes
to confirm your selection.
6.
Press Esc to return to the Tools Management menu.
Disable the HP NetRAID BIOS
If you want to prevent the system from booting from the integrated HP NetRAID
controller, you can disable the HP NetRAID BIOS.
To disable the HP NetRAID BIOS:
1.
If you have installed one or more HP NetRAID-3Si adapters, select the
integrated controller or adapter on which you want to disable the BIOS.
Choose
Select Adapter
from the Tools Management menu.
Select the adapter for which you want to disable the BIOS.
2.
Choose
Disable BIOS
from the Tools Management menu.
Exit HP NetRAID Express Tools
To exit HP NetRAID Express Tools, press Esc repeatedly until the Exit? prompt
is displayed. Choose
Yes
. Then press any key to reboot. The new parameters
become effective after you reboot.