Intel SR1530HCLRNA User Guide - Page 100

Replacing the Power Supply SR1530HCL, SR1530HCLS and SR1530HCLR/SR1530HCLSR

Page 100 highlights

Replacing the Power Supply (SR1530HCL/ SR1530HCLS and SR1530HCLR/SR1530HCLSR) The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, use the following instructions. 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information" on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct" on page 32. 5. Disconnect all power cables connected to the server board and peripherals: - A: Aux power signal - B: 2x12 main power connector - C: 2x4 power connector - D: Daisy-chain cable to optical drive power, if optical drive is installed. - E: 2x4 backplane power connector 78 Server System User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

78
Server System User Guide
Replacing the Power Supply (SR1530HCL/
SR1530HCLS and SR1530HCLR/SR1530HCLSR)
The power supply can be replaced if it fails or if one of the fans that is integrated into it
fails. To replace the power supply, use the following instructions.
1.
Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the server system cover. For instructions, see
“Removing the Server
System Cover”
.
4.
Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct” on page 32
.
5.
Disconnect all power cables connected to the server board and peripherals:
A: Aux power signal
B: 2x12 main power connector
C: 2x4 power connector
D: Daisy-chain cable to optical drive power, if optical drive is installed.
E: 2x4 backplane power connector