Intel SR1530HCLRNA User Guide - Page 80

Removing a Slimline Optical Drive SR1530CL/SR1530CLR

Page 80 highlights

Removing a Slimline Optical Drive (SR1530CL/SR1530CLR) 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information" on page iii. 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Server System Cover" on page 28. 4. Remove the front bezel if it is installed. For instructions, see "Removing the Front Bezel" on page 26. 5. Note the orientation of the PCI cooling fan that is located behind the optical drive bay, then lift the fan from the mounting pegs. It is not necessary to disconnect the fan cable. See letter "A" in the following figure. A AF000988 Figure 56. Lifting PCI Cooling Fan from Mounting Pegs (SR1530CL/ SR1530CLR) 6. Disconnect the optical drive power and data cables. See letters "A" and "B" in the following figure. 7. Remove the screw that holds the optical drive bracket to the server chassis. See letter "C". Save this screw. You will reinstall it later. 8. Slide the optical drive out through the front of the system. See letter "D". 58 Server System User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

58
Server System User Guide
Removing a Slimline Optical Drive (SR1530CL/SR1530CLR)
1.
Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the server system cover. For instructions, see
“Removing the Server
System Cover” on page 28
.
4.
Remove the front bezel if it is installed. For instructions, see
“Removing the Front
Bezel” on page 26
.
5.
Note the orientation of the PCI cooling fan that is located behind the optical drive
bay, then lift the fan from the mounting pegs. It is not necessary to disconnect the
fan cable. See letter “A” in the following figure.
Figure 56. Lifting PCI Cooling Fan from Mounting Pegs (SR1530CL/
SR1530CLR)
6.
Disconnect the optical drive power and data cables. See letters “A” and “B” in the
following figure.
7.
Remove the screw that holds the optical drive bracket to the server chassis. See
letter “C”. Save this screw. You will reinstall it later.
8.
Slide the optical drive out through the front of the system. See letter “D”.
A
AF000988