Konica Minolta AccurioPress C14000 Watkiss PowerSquare 224 Offline User Manual - Page 73

Action, Information, See Lubricate the Stitch Head

Page 73 highlights

5 - Error Conditions, Problems and Solutions - Clear a Stitch Head Jam Step 1 2 Action Lift the PowerSquare main deck. Remove the wire-holder from the stitch head. Information See "Lift the PowerSquare Main Deck" on page 30. • Move the wire-holder retaining spring to the right. See Figure 33 on page 68. • Remove the wire-holder. If the wire-holder is held in position, use a screw driver to help the removal of the wire-holder from the stitch head. CAUTION - Do not apply force to the wire guide bars or the pivot block. See Figure 34. 3 Inspect the area behind the wire- See Figure 34 on page 68. holder for pieces of stitch-wire. 4 Remove any stitches or pieces of Use the wire-cutters to remove stitch-wire and clean the area with any jammed stitches or pieces of the air-duster. stitch-wire. 5 Lubricate the stitch-head. See "Lubricate the Stitch Head" on page 83. 6 Fit the wire-holder. Remember to put the wire-holder retaining spring in position. 7 Close the PowerSquare. 8 Start the PowerSquare. If the head operates normally and returns to the parked position, then further action is not needed. If the stitch head remains jammed, then repeat the procedure one time. If the problem continues, then contact your Watkiss service engineer. Watkiss PowerSquare™224 User Manual 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

5 - Error Conditions, Problems and Solutions - Clear a Stitch Head Jam
Watkiss PowerSquare™224 User Manual
69
Step
Action
Information
1
Lift the PowerSquare main deck.
See “Lift the PowerSquare Main
Deck” on page 30.
2
Remove the wire-holder from the
stitch head.
Move the wire-holder retaining
spring to the right. See
Figure 33 on page 68.
Remove the wire-holder.
If the wire-holder is held in posi-
tion, use a screw driver to help the
removal of the wire-holder from
the stitch head.
CAUTION
- Do not apply force to
the wire guide bars or the pivot
block.
See Figure 34.
3
Inspect the area behind the wire-
holder for pieces of stitch-wire.
See Figure 34 on page 68.
4
Remove any stitches or pieces of
stitch-wire and clean the area with
the air-duster.
Use the wire-cutters to remove
any jammed stitches or pieces of
stitch-wire.
5
Lubricate the stitch-head.
See “Lubricate the Stitch Head” on
page 83.
6
Fit the wire-holder.
Remember to put the wire-holder
retaining spring in position.
7
Close the PowerSquare.
8
Start the PowerSquare.
If the head operates normally and
returns to the parked position, then
further action is not needed.
If the stitch head remains jammed,
then repeat the procedure one
time.
If the problem continues, then con-
tact your Watkiss service engineer.