Yamaha PM5000 Owner's Manual - Page 73

Direct Recall/ Mute Master Parameter No. U20, Scene Assignment

Page 73 highlights

Digital Control Section Direct Recall/ Mute Master (Parameter No. U20) In addition to their normal function as mute master switches, the console's 8 MUTE MASTER switches can also be used as DIRECT RECALL switches for scene recall. In this case the scene numbers to be recalled by each direct recall switch must be assigned as described below. D.RCL/M.MSTR Press [ENTER] after selecting the above display and a display like the one shown below will appear. Use the [INC] and [DEC] keys to select MUTE MASTER (mute master operation) or DIR RECALL (direct scene recall operation). MUTE MASTER DIR RECALL Lights when "MUTE MASTER" selected. Lights when "DIR RECALL" selected. ● Scene Assignment 1 Press [ENTER] after selecting "DIR RECALL" to move on to scene assignment. The parameter display should look like this. DIR1:--- "DIR1" through "DIR8" on the display corresponds to MUTE MASTER switches [1] through [8]. 2 Use the [INC] and [DEC] keys to select the switch for which a scene assignment is to be made and press the [ENTER] key. When the scene number parameter (rightmost) parameter begins flashing use the [INC] and [DEC] keys or the alpha-numeric keypad to enter the number of the scene to be recalled by that switch, and press [ENTER] again. Unassigned status "---" also can be selected. DIR1:128 3 Assign scene numbers to the remaining switches in the same way. NOTE Switches that you don't intend to use can be left unassigned ("---" on the display). Unassigned status will also automatically be set if an assigned scene is cleared to "NO DATA" status using the U06 utility function. Also, if the scenes are re-ordered the switch assignments will be automatically changed accordingly. NOTE When the MUTE MASTER switches are set for direct recall operation, the only master mute function that will apply to the input channels is VCA muting (page 24). Unassigned switches cannot be used for group muting. Mute master control via MIDI control change messages is also disabled. NOTE The mode cannot be switched to "DIR RECALL" while any of the switches are engaged in mute master mode. Disengage all mute masters prior to changing the setting. 71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

71
Digital Control Section
Direct Recall/ Mute Master (Parameter No. U20)
In addition to their normal function as mute master
switches, the console’s 8 MUTE MASTER switches can
also be used as DIRECT RECALL switches for scene
recall. In this case the scene numbers to be recalled by
each direct recall switch must be assigned as described
below.
Press [ENTER] after selecting the above display and a
display like the one shown below will appear. Use the
[INC] and [DEC] keys to select MUTE MASTER (mute
master operation) or DIR RECALL (direct scene recall
operation).
Scene Assignment
1
Press [ENTER] after selecting “DIR RECALL” to
move on to scene assignment. The parameter display
should look like this.
“DIR1” through “DIR8” on the display corresponds
to MUTE MASTER switches [1] through [8].
2
Use the [INC] and [DEC] keys to select the switch
for which a scene assignment is to be made and press
the [ENTER] key. When the scene number parameter
(rightmost) parameter begins flashing use the [INC]
and [DEC] keys or the alpha-numeric keypad to enter
the number of the scene to be recalled by that switch,
and press [ENTER] again. Unassigned status “---”
also can be selected.
3
Assign scene numbers to the remaining switches in
the same way.
NOTE
The mode cannot be switched to “DIR RECALL” while any of
the switches are engaged in mute master mode. Disengage all
mute masters prior to changing the setting.
D.RCL/M.MSTR
MUTE MASTER
DIR
RECALL
Lights when “MUTE MASTER” selected.
Lights when “DIR RECALL” selected.
NOTE
Switches that you don’t intend to use can be left unassigned (“---”
on the display). Unassigned status will also automatically be set if
an assigned scene is cleared to “NO DATA” status using the U06
utility function. Also, if the scenes are re-ordered the switch
assignments will be automatically changed accordingly.
NOTE
When the MUTE MASTER switches are set for direct recall
operation, the only master mute function that will apply to the
input channels is VCA muting (page 24).
Unassigned switches
cannot be used for group muting. Mute master control via MIDI
control change messages is also disabled.
DIR1:---
DIR1:128