Yamaha PM5000 Owner's Manual - Page 78

Cascade Parameter No. U23, VCA Group 1 ~ 12, Mute Group 1 ~ 8, Cue Solo Function, Scene Recall

Page 78 highlights

Digital Control Section Cascade (Parameter No. U23) To allow fuss-free type A connection of PM5000 consoles, the PM5000 is shipped from the factory with all of the function links listed in the above chart ON. If you want to turn some of these off, use the following parameter on the slave PM5000. In a type B connection, turn the master PM5000 console CUE/SOLO function link ON if you want to enable cue/solo control from the slave console. NOTE If the physical cascade connection and hardware MASTER/ SLAVE selection has been completed, the following parameters turn function linking on or off the instant they are set. If a link is turned OFF it may be impossible to reproduce the previous slave settings. To avoid confusion it is advisable to make the hardware connections and settings after setting the software parameters. Cue Solo Function CUE/SOL:ON Scene Recall SCN RCL:ON Scene Store SCN STR:ON 2 Use the [INC] and [DEC] keys to turn linking of the selected function ON or OFF. SCN STR:OFF CASCADE 3 Set the links for other functions in the same way, as required. 1 Press [ENTER] after selecting the above display and a display like the one shown below will appear. Use the [INC] and [DEC] keys or the alpha-numeric keypad to select VCA1 ~ VCA12 (VCA groups 1 ~ 12), MUTE1 ~ MUTE8 (mute groups 1 ~ 8), CUE/ SOL (the cue/solo function), SCN RCL (scene recall), or SCN STR (scene store), and then press the [ENTER] key. VCA Group 1 (~ 12) VCA01:ON Mute Group 1 (~ 8) MUTE1:ON 76

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

76
Digital Control Section
Cascade (Parameter No. U23)
To allow fuss-free type A connection of PM5000
consoles, the PM5000 is shipped from the factory with
all of the function links listed in the above chart ON. If
you want to turn some of these off, use the following
parameter on the slave PM5000. In a type B connection,
turn the master PM5000 console CUE/SOLO function
link ON if you want to enable cue/solo control from the
slave console.
1
Press [ENTER] after selecting the above display and
a display like the one shown below will appear. Use
the [INC] and [DEC] keys or the alpha-numeric
keypad to select VCA1 ~ VCA12 (VCA groups 1 ~
12), MUTE1 ~ MUTE8 (mute groups 1 ~ 8), CUE/
SOL (the cue/solo function), SCN RCL (scene
recall), or SCN STR (scene store), and then press the
[ENTER] key.
VCA Group 1 (~ 12)
Mute Group 1 (~ 8)
Cue Solo Function
Scene Recall
Scene Store
2
Use the [INC] and [DEC] keys to turn linking of the
selected function ON or OFF.
3
Set the links for other functions in the same way, as
required.
NOTE
If the physical cascade connection and hardware MASTER/
SLAVE selection has been completed, the following parameters
turn function linking on or off the instant they are set. If a link is
turned OFF it may be impossible to reproduce the previous slave
settings. To avoid confusion it is advisable to make the hardware
connections and settings after setting the software parameters.
CASCADE
VCA01:ON
MUTE1:ON
CUE/SOL:ON
SCN RCL:ON
SCN STR:ON
SCN STR:OFF