Extended AT& Command Set
View all ZyXEL Omni TA 128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Extended "AT&" Command Set Command Options Function and Description Ref. &Cn Carrier Detect (CD) options &C1 * CD tracks presence of carrier All other values are invalid &Dn Data Terminal Ready (DTR) options. &D2 * 108.2, Data Terminal Ready, DTR OFF causes the TA to hang up. All other values are invalid &En B channel line speed for ISDN S128.2 data call &E0 * 64Kbps &E1 56Kbps (Default for American ISDN) &F Load factory settings to RAM as the active configuration. &Hn Data flow control, DTE/DCE. &H3 * Hardware (CTS/RTS) flow control All other values are invalid &On Set default call type for conventional dialing commands &O2 * ATDs, ATDPs, and ATDTs default to make ISDN data calls All other values are invalid &Sn Data Set Ready (DSR) function selection. &S0 * DSR overridden, DSR always ON. All other values are invalid &Vn View profile settings. &V0 View current active settings. &V5 View factory default settings. 101