ZyXEL Omni TA 128 User Guide - Page 58

Making V.110 Calls, Synchronous Connections

Page 58 highlights

the DCE will report "RING" and will also make an audible ring notification. Making V.110 Calls Before the ATDIxxx command is given to place the call, you need to make sure that the TA128 is in asynchronous mode (AT&M0). Then use the following commands to configure V.110: AT Command ATB10 ATB13 ATB14 ATB15 ATB16 ATB17 ATB18 ATB19 Description User rate follows DTE speed (see note below). User rate = 2400bps. User rate = 4800bps. User rate = 9600bps. User rate = 14400bps. User rate = 19200bps. User rate = 38400bps. User rate = 57600bps (Japanese version only). The highest Async V.110 user rate depends on bit 4 of S119 as follows: S119.4=0 S119.4=1 S119.4=1 19200 bps. 38400 bps for areas other than Japan (default). 57600 bps for Japanese version. If the DTE speed is higher than what has been set, the user rate on above table will be used. Synchronous Connections Use the following commands to choose the data rate for synchronous operation : ATB11 64000bps 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173

46
the DCE will report “RING” and will also make an audible ring
notification.
Making V.110 Calls
Before the
ATDIxxx
command is given to place the call, you need
to make sure that the TA128
is in asynchronous mode (AT&M0).
Then use the following commands to configure V.110:
AT Command
Description
ATB10
User rate follows DTE speed (see note below).
ATB13
User rate = 2400bps.
ATB14
User rate = 4800bps.
ATB15
User rate = 9600bps.
ATB16
User rate = 14400bps.
ATB17
User rate = 19200bps.
ATB18
User rate = 38400bps.
ATB19
User rate = 57600bps (Japanese version only).
The highest Async V.110 user rate depends on bit 4 of S119 as
follows:
S119.4=0
19200 bps.
S119.4=1
38400 bps for areas other than Japan (default).
S119.4=1
57600 bps for Japanese version.
If the DTE speed is higher than what has been set, the user rate on
above table will be used.
Synchronous Connections
Use the following commands to choose the data rate for
synchronous operation :
ATB11
64000bps