ZyXEL Omni TA 128 User Guide - Page 148
Ignore S21.1-2 when Phone 1
View all ZyXEL Omni TA 128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 148 highlights
Command bit dec hex Function and description Ref. 3-5 0 0 ATX0 (See result code table). 8 8 ATX1 dec hex AT 16 10 ATX2 40 28 X5 24 18 ATX3 48 30 X6 32 20 ATX4 56 38 X7 6 0 0 Display result code in numeric V0 format (see S35.7). 64 40 Display result code in verbose V1 format. 7 0 0 TA returns result code. Q0 128 80 TA does not return result code Q1 (see S40b1). S24= bit dec hex Bit mapped register. 0-1 0-3 0-3 Ring volume control, N0-3 increments of 1 in decimal. 2 0 0 Ignore S21.1-2 when Phone 1 key pad dialed. 4 4 Do not ignore S21-2 when Phone 1 key pad dialed. 3 0 0 Ignore S21.1-2 when Phone 2 key pad dialed. 8 8 Do not ignore S21-2 when Phone 2 key pad dialed. 4-5 16- Speaker volume control, in L0-3 48 increments of 16 in decimal value. 6 0 0 POTS Port tone volume low. 1 1 POTS Port tone volume high. S27= bit dec hex Bit mapped register. 3-5 0 0 Flow control disabled. &H0 24 18 Hardware (RTS/CTS) flow &H3 control. 136