Brother International HL 5030 Service Manual - Page 120
MP Unit (for HL-5050/5070N only), Remove the MP solenoid holder unit.
View all Brother International HL 5030 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
HL-5030/5040/5050/5070N SERVICE MANUAL 3.12 MP Unit (for HL-5050/5070N only) (1) Disconnect the two connectors. (2) Remove the MP ground spring. (3) Remove the two bind B M3x10 and cup S M3x6 Taptite screws. (4) Remove the MP solenoid holder unit. MP ground spring MP solenoid holder unit Engine PCB connector Taptite, bind B M3x10 MP sensor harness Taptite, cup S M3x6 Fig. 4-38 (5) Remove the cup S M3x6 Taptite screw, and then open the MP chute ASSY cover. (6) Remove the paper pick-up roller ASSY from the shaft. Paper pick-up roller ASSY Hook MP chute ASSY cover Taptite, cup S M3x6 Shaft Fig. 4-39 4-23
HL-5030/5040/5050/5070N SERVICE MANUAL
4-23
3.12
MP Unit (for HL-5050/5070N only)
(1) Disconnect the two connectors.
(2) Remove the MP ground spring.
(3)
Remove the two bind B M3x10 and cup S M3x6 Taptite screws.
(4) Remove the MP solenoid holder unit.
Fig. 4-38
(5)
Remove the cup S M3x6 Taptite screw, and then open the MP chute ASSY cover.
(6)
Remove the paper pick-up roller ASSY from the shaft.
Fig. 4-39
MP ground spring
Paper pick-up roller ASSY
Taptite, cup S M3x6
MP chute ASSY cover
MP sensor harness
Hook
Shaft
Engine PCB
connector
Taptite, bind B
M3x10
MP solenoid holder unit