Dell PowerEdge 840 Hardware Owner's Manual (PDF) - Page 35

Console Redirection Screen, System Security Screen, Console, Redirection - nic

Page 35 highlights

Table 2-4. Integrated Devices Screen Options (continued) Option Serial Port (COM1 default) Speaker (On default) Description Serial Port options are COM1, COM3, BMC Serial, BMC NIC, COM1/BMC, and Off. If an optional remote access controller (RAC) is installed in the system, RAC is an additional option. Serial Port shares three usage models. For standard usage, Serial Port attempts to use COM1 first, and then COM3. For BMC usage, serial port 1 uses the COM1 address and communication can be either via the serial port or the integrated shared NIC. RAC control uses only the COM1 address. The COM1/BMC setting allows you to toggle the system between a COM1 setting and BMC Serial setting. In this mode, press to enter the BMC Serial setting and press to return to the COM1 setting. Off and COM3 are not available options when Console Redirection is set to use Serial Port 1. Enables or disables the system internal speaker. Console Redirection Screen Table 2-5 lists the options and descriptions for the information fields that appear on the Console Redirection screen. Table 2-5. Console Redirection Screen Options Option Console Redirection (Off default) Failsafe Baud Rate (11520 default) Remote Terminal Type (VT 100/VT 220 default) Redirection After Boot (Enabled default) Description Sets the console redirection feature to Serial Port or Off. Displays if the failsafe baud rate is used for console redirection. Select either VT 100/VT 220 or ANSI. Enables or disables console redirection after your system restarts. System Security Screen Table 2-6 lists the options and descriptions for the information fields that appear on the System Security screen. Using the System Setup Program 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Using the System Setup Program
35
Console Redirection Screen
Table 2-5 lists the options and descriptions for the information fields that appear on the
Console
Redirection
screen.
System Security Screen
Table 2-6 lists the options and descriptions for the information fields that appear on the
System Security
screen.
Serial Port
(
COM1
default)
Serial Port
options are
COM1
,
COM3
,
BMC Serial
,
BMC NIC
,
COM1/BMC
,
and
Off
. If an optional remote access controller (RAC) is installed in the system,
RAC
is an additional option.
Serial Port
shares three usage models. For standard usage,
Serial Port
attempts to
use COM1 first, and then COM3. For BMC usage, serial port 1 uses the COM1
address and communication can be either via the serial port or the integrated
shared NIC. RAC control uses only the COM1 address.
The
COM1/BMC
setting allows you to toggle the system between a
COM1
setting and
BMC Serial
setting. In this mode, press <ESC> to enter the BMC
Serial setting and press <ESC><q> to return to the
COM1
setting.
Off
and
COM3
are not available options when Console Redirection is set to use
Serial Port 1.
Speaker
(
On
default)
Enables or disables the system internal speaker.
Table 2-5.
Console Redirection Screen Options
Option
Description
Console Redirection
(
Off
default)
Sets the console redirection feature to
Serial Port
or
Off
.
Failsafe Baud Rate
(
11520
default)
Displays if the failsafe baud rate is used for console redirection.
Remote Terminal Type
(
VT 100/VT 220
default)
Select either
VT 100/VT 220
or
ANSI
.
Redirection After Boot
(
Enabled
default)
Enables or disables console redirection after your system restarts.
Table 2-4.
Integrated Devices Screen Options
(continued)
Option
Description