Dell PowerEdge 840 Hardware Owner's Manual (PDF) - Page 97
Troubleshooting a Damaged System, see Getting Help
View all Dell PowerEdge 840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
5 Close the system. See "Closing the System" on page 47. 6 Reconnect the system to the electrical outlet, and turn on the system and attached peripherals. If the system does not start properly, see "Getting Help" on page 121. 7 If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed. See "Installing an Expansion Card" on page 72. 8 Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 111. If the tests fail, see "Getting Help" on page 121. Troubleshooting a Damaged System Problem • System was dropped or damaged. Action CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge. 1 Open the system. See "Opening the System" on page 43. 2 Ensure that the following components are properly installed: • Expansion cards • Power supplies • Fans • Processors and heat sinks • Memory modules • Drive-carrier connections to the backplane board, if applicable 3 Ensure that all cables are properly connected. 4 Close the system. See "Closing the System" on page 47. 5 Run the system board tests in the system diagnostics. See "Using Dell PowerEdge Diagnostics" on page 111. If the tests fail, see "Getting Help" on page 121. Troubleshooting Your System 97