Dell PowerEdge 840 Hardware Owner's Manual (PDF) - Page 65
Installing the Cooling Shroud, Cooling Fans - raid configuration
View all Dell PowerEdge 840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Figure 3-14. Removing the Cooling Shroud 1 2 3 1 shroud release tab 2 anchor tabs (2) 3 cooling shroud Installing the Cooling Shroud 1 Ensure that no tools or loose parts are left inside the system. 2 Align the anchor tabs on the cooling shroud with the notches in the system chassis. 3 Reposition the SAS or SATA cables and power cables so they do not obstruct the memory modules and interfere with installing the cooling shroud. 4 Gently lower the cooling shroud until the shroud release tab on the back panel snaps into place. 5 Reconnect the power cable(s) to the SAS backplane (if applicable) or the hard drive(s). Cooling Fans The system includes the following cooling fans: • Front system fan (only when configured with optional SAS or RAID controller cards) • Back system fan Installing System Components 65