HP StorageWorks 2/16V Brocade Fabric OS Documentation Addendum - Supporting Fa - Page 41

fwClassInit, fwConfigReload, fwShow, To con thresholds in Access Gateway mode

Page 41 highlights

fwConfigure 1 Examples To configure thresholds in Access Gateway mode: ST3:admin> fwconfigure 1 : Environment class 2 : SFP class 3 : Port class 4 : F/FL Port (Optical) class 5 : Resource class 6 : quit Select a class => : (1..6) [6] 1 1 : Temperature 2 : Fan 3 : Power Supply 4 : return to previous page Select an area => : (1..4) [4] 1 Index ThresholdName Status CurVal LastEvent LasteventTime LastVal LastState 1 envTemp001 enabled 23 C inBetween Sat Oct 7 10:01:53 2006 21 C In_Range 2 envTemp002 enabled 24 C inBetween Sat Oct 7 10:01:53 2006 21 C In_Range 1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow Fabric OS Documentation Addendum Publication Number: 53-1000429-01-HP 1-27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Fabric OS Documentation Addendum
1-27
Publication Number: 53-1000429-01-HP
fwConfigure
1
Examples
To configure thresholds in Access Gateway mode:
See Also
fwClassInit
,
fwConfigReload
,
fwShow
ST3:admin> fwconfigure
1
: Environment class
2
: SFP class
3
: Port class
4
: F/FL Port (Optical) class
5
: Resource class
6
: quit
Select a class => : (1..6) [6] 1
1 : Temperature
2 : Fan
3 : Power Supply
4 : return to previous page
Select an area => : (1..4) [4] 1
Index ThresholdName
Status
CurVal
LastEvent
LasteventTime
LastVal
LastState
================================================================================
1
envTemp001
enabled
23 C
inBetween
Sat Oct
7 10:01:53 2006
21 C
In_Range
2
envTemp002
enabled
24 C
inBetween
Sat Oct
7 10:01:53 2006
21 C
In_Range
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select choice => : (1..5) [5] 5