HP StorageWorks 2/16V Brocade Fabric OS Documentation Addendum - Supporting Fa - Page 50

portCfg, portCfgPersistentDisable, portCfgNPIVPort, switchShow, rscnsupr, mirrorport, fciptunnel

Page 50 highlights

1 portCfgShow Note: Enter commands in lowercase only; mixed case is for readability RSCN Suppression Displays as ON when the port has RSCN suppression enabled or blank (..) when the port has RSCN suppression disabled. This value is set by the portCfg rscnsupr command. Persistent Disable Displays as ON when the port is persistently disabled. This value is set by the portCfgPersistentDisable command. Mirror Port Mode Displays as ON when the port has Mirror Port Mode enabled or blank (..) when the port has the Mirror Port Mode disabled. This value is set by the portCfg mirrorport command. NPIV capability Displays as ON when the port has N_Port ID Virtualization (NPIV) enabled or blank (..) when the port has the NPIV capability disabled. This value is set by the portCfgNPIVPort command. It is enabled by default for Condor-based ports and disabled by default for Bloom-based ports. Note The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: arp Displays address resolution protocol (ARP) table. fciptunnel Displays FCIP tunnels on this GbE port. Possible optional args include: all, which displays all FCIP tunnels; tunnel_id, which displays the specified FCIP tunnel; ipsec, which displays IKE and IPSec policy information on IPSec-enabled tunnels. ipif Displays the IP interface. iproute Displays the IP route. mode Displays mode of a GbE port. slotnumber For bladed systems only, specifies the slot number of the port to display, followed by a slash (/). portnumber Specifies the port number to display, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. This operand is optional; if omitted, this command displays information for all ports. 1-36 Fabric OS Documentation Addendum Publication Number: 53-1000429-01-HP

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

1-36
Fabric OS Documentation Addendum
Publication Number: 53-1000429-01-HP
portCfgShow
Note: Enter commands in lowercase only; mixed case is for readability
1
RSCN Suppression
Displays as ON when the port has RSCN suppression enabled or blank (..) when
the port has RSCN suppression disabled. This value is set by the
portCfg
rscnsupr
command.
Persistent Disable
Displays as ON when the port is persistently disabled. This value is set by the
portCfgPersistentDisable
command.
Mirror Port Mode
Displays as ON when the port has Mirror Port Mode enabled or blank (..) when
the port has the Mirror Port Mode disabled. This value is set by the
portCfg
mirrorport
command.
NPIV capability
Displays as ON when the port has N_Port ID Virtualization (NPIV) enabled or
blank (..) when the port has the NPIV capability disabled. This value is set by the
portCfgNPIVPort
command. It is enabled by default for Condor-based ports and
disabled by default for Bloom-based ports.
Note
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands
This command has the following operands:
arp
Displays address resolution protocol (ARP) table.
fciptunnel
Displays FCIP tunnels on this GbE port. Possible optional args include:
all
, which
displays all FCIP tunnels;
tunnel_id
, which displays the specified FCIP tunnel;
-
ipsec
, which displays IKE and IPSec policy information on IPSec-enabled
tunnels.
ipif
Displays the IP interface.
iproute
Displays the IP route.
mode
Displays mode of a GbE port.
slotnumber
For bladed systems only, specifies the slot number of the port to display, followed
by a slash (/).
portnumber
Specifies the port number to display, relative to its slot for bladed systems. Use
switchShow
to display a list of valid ports. This operand is optional; if omitted,
this command displays information for all ports.