HP StorageWorks 2/16V Brocade Fabric OS Documentation Addendum - Supporting Fa - Page 52

portCfg, portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgNPIVPort,

Page 52 highlights

1 portCfgShow Note: Enter commands in lowercase only; mixed case is for readability To display the configuration settings for a port: switch:user> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO Trunk Port ON Long Distance OFF VC Link Init OFF Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF ISL R_RDY Mode OFF RSCN Suppressed OFF Persistent Disable OFF NPIV capability ON Mirror Port OFF To display the configuration settings for a port with agmode enabled: SW4016_5311:admin> portcfgshow Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Locked N_Port ON ON .. ON ON ON Persistent Disable NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON where AN:AutoNegotiate, ..:OFF, ??:INVALID, SN:Software controlled AutoNegotiation. See Also portCfg, portCfgEPort, portCfgGPort, portCfgLongDistance, portCfgLPort, portCfgNPIVPort, portCfgSpeed, portCfgTrunkPort 1-38 Fabric OS Documentation Addendum Publication Number: 53-1000429-01-HP

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

1-38
Fabric OS Documentation Addendum
Publication Number: 53-1000429-01-HP
portCfgShow
Note: Enter commands in lowercase only; mixed case is for readability
1
To display the configuration settings for a port:
To display the configuration settings for a port with agmode enabled:
See Also
portCfg
,
portCfgEPort
,
portCfgGPort
,
portCfgLongDistance
,
portCfgLPort
,
portCfgNPIVPort
,
portCfgSpeed
,
portCfgTrunkPort
switch:user> portcfgshow 2/16
Area Number:
144
Speed Level:
AUTO
Trunk Port
ON
Long Distance
OFF
VC Link Init
OFF
Locked L_Port
OFF
Locked G_Port
OFF
Disabled E_Port
OFF
ISL R_RDY Mode
OFF
RSCN Suppressed
OFF
Persistent Disable
OFF
NPIV capability
ON
Mirror Port
OFF
SW4016_5311:admin> portcfgshow
Ports of Slot 0
0
1
2
3
4
5
6
7
8
9 10 11
12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed
AN AN AN AN
AN AN AN AN
AN AN AN AN
AN AN AN AN
Locked N_Port
.. .. .. ..
.. .. .. ..
.. .. ON ON
.. ON ON ON
Persistent Disable.. .. .. ..
.. .. .. ..
.. .. .. ..
.. .. .. ..
NPIV capability
ON ON ON ON
ON ON ON ON
ON ON ON ON
ON ON ON ON
where AN:AutoNegotiate, ..:OFF, ??:INVALID,
SN:Software controlled AutoNegotiation.