Table 2-4, SCSI Interface Mode Switch Settings, Do not use a physical terminator., Setting, Purpose
View all HP Surestore Tape Library Model 2/28 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Table 2-4 CAUTION Library Installation Step 4: Connect the Library to the Host 5. For each bus, set the SCSI interface mode switch as follows. SCSI Interface Mode Switch Settings Setting Term Pwr Termination Purpose Set to Sends termination ON power to the bus Terminates the SCSI bus; functions the same as a physical terminator ON if one port on the bus is open OFF if both ports on the bus are connected to a cable Do not use a physical terminator. If a physical terminator is attached and termination is set to ON, the bus will be overterminated, which could cause the device to function incorrectly. Library Installation 2-7
2-7
Library Installation
Step 4: Connect the Library to the Host
Library Installation
5.
For each bus, set the SCSI interface mode switch as follows.
Table 2-4
SCSI Interface Mode Switch Settings
CAUTION
Do not use a physical terminator.
If a physical terminator is attached and
termination is set to ON, the bus will be overterminated, which could cause
the device to function incorrectly.