HP Surestore Tape Library Model 2/28 HP DLT Tape Library 28/48-Slot - User& - Page 57

Setting the Robotics Controller Bus Type, ADMIN, SCSI IDs, SET LIB BUS, DIFFERENTIAL, SINGLE ENDED

Page 57 highlights

Library Operation Specifying SCSI Addresses Setting the Robotics Controller Bus Type 1 2 3 4 BUS* ADMIN* PSWD 000-000-000 SCSI IDs* SET LIB Two bus settings are available: • Differential • Single-ended To set the bus type: 1. Verify that the drive status displays (if not, press CANCEL until it does). 2. Press NEXT until ADMIN* displays, then press ENTER. 3. Enter the three-part numerical password (see "Entering the Administration Menu Password" on page 4-7). 4. Press NEXT until SCSI IDs* displays, then press ENTER. 5. Press NEXT until SET LIB BUS* displays, then press ENTER. DIFFERENTIAL displays. 6. Press NEXT to toggle between DIFFERENTIAL or SINGLE ENDED. Press ENTER to set the bus type. DIFFERENTIAL BUS or SINGLE ENDED BUS displays briefly, then SCSI IDs* displays. 7. Press CANCEL until the next operation to perform displays, or until the drive status (library "ready" state) displays. Library Operation 4-13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

4-13
Library Operation
Specifying SCSI Addresses
Library Operation
Setting the Robotics Controller Bus Type
1 2 3 4 ADMIN* PSWD 000-000-000 SCSI IDs*
SET LIB
BUS*
Two bus settings are available:
Differential
Single-ended
To set the bus type:
1.
Verify that the drive status displays (if not, press
CANCEL
until it does).
2.
Press
NEXT
until
ADMIN*
displays, then press
ENTER
.
3.
Enter the three-part numerical password (see “Entering the
Administration Menu Password” on page 4-7).
4.
Press
NEXT
until
SCSI IDs*
displays, then press
ENTER
.
5.
Press
NEXT
until
SET LIB BUS*
displays, then press
ENTER
.
DIFFERENTIAL
displays.
6.
Press
NEXT
to toggle between
DIFFERENTIAL
or
SINGLE ENDED
. Press
ENTER
to set the bus type.
DIFFERENTIAL BUS
or
SINGLE ENDED BUS
displays briefly, then
SCSI IDs*
displays.
7.
Press
CANCEL
until the next operation to perform displays, or until the
drive status (library “ready” state) displays.