HP Surestore Tape Library Model 2/28 HP DLT Tape Library 28/48-Slot - User& - Page 81

Table 4-10, Tests Available from the Control Panel

Page 81 highlights

Library Operation Running an Internal Test Table 4-10 Tests Available from the Control Panel Test Name Description EXERCISE MECH Runs the VERTICAL TEST, TRANSLATE TEST, MAGAZINE IO, DRIVE IO, and MAILSLOT IO tests. Each test is run one time per test loop. EXCHANGE DEMO Do not run test if library contains customer data cartridges. Moves randomly-chosen cartridges to random storage slot locations. This test displays FAIL if there are no cartridges in the library or if all storage slots are full. For best results, the library should contain as many cartridges as there are drives, plus two additional cartridges. The transport and mailslot must be empty. IO DRIVE Makes a combination of moves with a PASS/FAIL result. It moves a tape cartridge from a randomly- chosen full slot to a randomly-chosen drive. It then moves the cartridge back to its original slot. This test displays FAIL if there are no cartridges in the library or if all storage slots are full. The drives, transport, and mailslot must be empty. IO MAGAZINE Makes a combination of moves with a PASS/FAIL result. It moves a tape cartridge from a randomly-chosen full slot to a randomly-chosen empty slot. It then moves the tape back to its original storage slot. This test displays FAIL if there are no cartridges in the library or if all storage slots are full. The drives, transport, and mailslot must be empty. IO MAILSLOT Makes a combination of moves with a PASS/FAIL result. It moves a tape cartridge from a randomly-chosen full slot to the mailslot. It then moves the cartridge back to its original slot. This test displays FAIL if there are no cartridges in the library or if all storage slots are full. The drives, transport, and mailslot must be empty. INVENTORY CHECK Functions the same as the SCSI Initialize Element Status (ISTAT) command. This test physically scans the entire unit to determine which storage slots contain tape cartridges and if the drives contain cartridges. NOTE: This test appears as "INVENTORY CHECK" in all control panel error messages. TEST TRANSLATE Translates from side to side. No tape cartridges are required. TEST VERTICAL Moves the transport mechanism up and down the full length of the rail. Returns PASS/FAIL. No tape cartridges are required. WELLNESS TEST Checks out the general capability of the library. Runs INIT MECHANICS and EXERCISE MECH. Each test is run one time per test loop. Library Operation 4-37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

4-37
Library Operation
Running an Internal Test
Library Operation
Table 4-10
Tests Available from the Control Panel
Test Name
Description
EXERCISE MECH
Runs the
VERTICAL TEST
,
TRANSLATE TEST
,
MAGAZINE IO
,
DRIVE IO
, and
MAILSLOT IO
tests. Each test is run one time per test loop.
EXCHANGE DEMO
Do not run test if library contains customer data cartridges.
Moves randomly-chosen cartridges to random storage slot locations. This test
displays
FAIL
if there are no cartridges in the library or if all storage slots are
full. For best results, the library should contain as many cartridges as there are
drives, plus two additional cartridges. The transport and mailslot must be empty.
IO DRIVE
Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly- chosen full slot to a randomly-chosen drive. It then
moves the cartridge back to its original slot. This test displays
FAIL
if there are
no cartridges in the library or if all storage slots are full. The drives, transport,
and mailslot must be empty.
IO MAGAZINE
Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly-chosen full slot to a randomly-chosen empty slot. It
then moves the tape back to its original storage slot. This test displays
FAIL
if
there are no cartridges in the library or if all storage slots are full. The drives,
transport, and mailslot must be empty.
IO MAILSLOT
Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly-chosen full slot to the mailslot. It then moves the
cartridge back to its original slot. This test displays
FAIL
if there are no
cartridges in the library or if all storage slots are full. The drives, transport, and
mailslot must be empty.
INVENTORY
CHECK
Functions the same as the SCSI Initialize Element Status (ISTAT) command.
This test physically scans the entire unit to determine which storage slots contain
tape cartridges and if the drives contain cartridges.
NOTE: This test appears as
“INVENTORY CHECK” in all control panel error messages.
TEST
TRANSLATE
Translates from side to side. No tape cartridges are required.
TEST VERTICAL
Moves the transport mechanism up and down the full length of the rail.
Returns PASS/FAIL. No tape cartridges are required.
WELLNESS TEST
Checks out the general capability of the library. Runs INIT MECHANICS
and EXERCISE MECH. Each test is run one time per test loop.