Sending a Test call Acknowledgment

Page 42 highlights

6 DSC OPERATION ■ Sending DSC calls (other) D Sending a Test call (Continued) 6. Select "Call Frequency." Rotate + Push 7. Select a call frequency. Rotate + Push 8. Push Call to send a Test call. • "Transmitting Test Call" is displayed, and then "Test Call" is displayed.  See page 23 for details of the Software Key functions in the DSC Task mode. 9. Push Standby Mode , and then OK to return to the Main screen. D Sending a Test call Acknowledgment When you have received a Test call (p. 45), send an Acknowledgment to the calling station. When "Test ACK" is set to "Manual" (p. 49), do the following steps to send an Acknowledgment. 1. While a Test call is being received, push Alarm Off to turn OFF the alarm. 2. Push Accept . • The received call's information is displayed.  If you want to immediately send an Acknowledgment "Able to comply," push Able .  If you cannot communicate and want to return to the Main screen, push Ignore .  If you want to put the task on hold, push Hold . 3. Push ACK . • The Call Contents screen is displayed. 4. Confirm the contents. Rotate 5. Push Call to send a Test Acknowledgment. 6. Push Standby Mode , and then OK to return to the Main screen. TIP: When "Test ACK" is set to "Auto," the transceiver automatically transmits a Test Acknowledgment. (p. 49) 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

37
6
DSC OPERATION
Sending DSC calls (other)
D
Sending a Test call (Continued)
6. Select “Call Frequency.”
7.
Select a call frequency.
8. Push
Call
to send a Test call.
“Transmitting Test Call” is displayed, and then
“Test Call” is displayed.
See page 23 for details of the Software Key
functions in the DSC Task mode.
9.
Push
Standby Mode
, and then
OK
to
return to the Main screen.
D
Sending a Test call Acknowledgment
When you have received a Test call (p. 45), send
an Acknowledgment to the calling station. When “Test
ACK” is set to “Manual” (p. 49), do the following
steps to send an Acknowledgment.
1.
While a Test call is being received, push
Alarm Off
to turn OFF the alarm.
2. Push
Accept
.
The received call’s information is displayed.
If you want to immediately send an Acknowledgment
“Able to comply,” push
Able
.
If you cannot communicate and want to return to the
Main screen, push
Ignore
.
If you want to put the task on hold, push
Hold
.
3. Push
ACK
.
The Call Contents screen is displayed.
4. Confirm the contents.
5. Push
Call
to send a Test Acknowledgment.
6. Push
Standby Mode
, and then
OK
to
return to the Main screen.
TIP:
When “Test ACK” is set to “Auto,” the transceiver
automatically transmits a Test Acknowledgment.
(p. 49)
+