Icom IC-M804 Instruction Manual - Page 74
MB-108 installation, CAUTION: KEEP, CAUTION
View all Icom IC-M804 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
8 CONNECTIONS AND INSTALLATION ■■MB-108 installation The optional MB-108 mounting bracket is for mounting the Main unit to a flat surface (less than 25 mm thick and can support more than 15 kg), such as an instrument panel. The MB-108 provides a one-touch attachment or detachment. 1. Attach the mounting handles with the 6 supplied hex head bolts (6 × 15 mm), 6 spring and flat washers, as shown below. Hex head bolt (6 × 15 mm) Spring washer Flat washer CAUTION: KEEP the transceiver and microphone at least 1 meter away from your vessel's magnetic navigation compass. CAUTION: Wear gloves when installing the MB-108. The edges of the MB-108 may be sharp and may cut your fingers or hands. 4. Mount the Main unit with the mounting handles attached to the mounting base. Mounting handle 2. Drill 7 holes, 6 ~ 8 mm in diameter, using the template supplied with the MB-108. 3. Attach the mounting base to a flat surface using the 7 hex head bolts (6 × 50 mm), 14 spring and flat washers, and 7 nuts supplied with the MB-108, as shown below. (Torque: 3 N•m) Hex head bolt (6 × 50 mm) Spring washer Flat washer 5. Lock the Main unit in place by closing the 4 latches on the mounting handles. x z Mounting base Flat washer Spring washer Nut (M6) 69