Icom IC-M804 Instruction Manual - Page 46
Receiving DSC calls (other), Receiving an Individual call
View all Icom IC-M804 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
6 DSC OPERATION ■ Receiving DSC calls (other) D Receiving an Individual call NOTE: • To receive an Individual call, push [D-SCAN] to enter the DSC watch mode. (p. 10) • When "Individual ACK" is set to "Auto (Able)" or "Auto (Unable)," the transceiver automatically sends an Acknowledgment "Able to comply" or "Unable to comply." (p. 49) In that case, both the TX and RX calls are saved in the Transmitted and Received Call Logs. (p. 46) When an Individual call is received: • The alarm sounds until you turn it OFF. • "Received Individual Call" is displayed. 1. Push Alarm Off to turn OFF the alarm. 3. Push a key to select an Acknowledgment option. • The Call Contents screen is displayed. 2. Push the Software Key below the intended operation. 4. Confirm the contents. Rotate Ignore Hold Able Accept : Ignores the call and returns to the Main screen. : Puts the RX task on hold and returns to the Main screen. : Sends an Acknowledgment "Able to comply" without any changes. : Enters the DSC Task mode immediately. NOTE: When Accept is selected in this step, an Acknowledgment can be send in the DSC Task mode. To send the Acknowledgment, go to step 3. To return to the Main screen without sending the Acknowledgment, go to step 7. 5. Push Call to send an Individual Acknowledgment. 6. Hold down [PTT] to talk. 7. Push Standby Mode , and then OK to return to the Main screen. TIP: When sending the Acknowledgment, select one of three options, depending on your situation. See pages 30 and 31 for details of the Individual Acknowledgment procedures. 41