Icom IC-M804 Instruction Manual - Page 50
Receiving a Test call, Receiving a Test Acknowledgment, When a Test call is received
View all Icom IC-M804 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
6 DSC OPERATION ■ Receiving DSC calls (other) D Receiving a Test call NOTE: When "Test ACK" is set to "Auto," the transceiver automatically sends an Acknowledgment. (p. 49) In that case, both the TX and RX calls are saved in the Transmitted and Received Call Logs. (p. 46) When a Test call is received: • The alarm sounds until you turn it OFF. • "Received Test Call" is displayed. 1. Push Alarm Off to turn OFF the alarm. D Receiving a Test Acknowledgment When a Test Acknowledgment is received: • The alarm sounds until you turn it OFF. • "Received Test ACK" is displayed. 1. Push Alarm Off to turn OFF the alarm. 2. Push Close Call RCVD Window . 2. Push the Software Key below the intended operation. Rotate Ignore Hold Able Accept : Ignores the call and returns to the Main screen. : Puts the RX task on hold and returns to the Main screen. : Sends an Acknowledgment "Able to comply." : Immediately enters the DSC Task mode. Rotate [CH/GRP] to confirm the call contents. See page 23 for details of the Software Key functions in the DSC Task mode. 3. Push Standby Mode , and then OK to return to the Main screen. Rotate Rotate [CH/GRP] to confirm the call contents. See page 23 for details of the Software Key functions in the DSC Task mode. 3. Push Standby Mode , and then OK to return to the Main screen. TIP: See page 37 for details of the Test Acknowledgment procedures. 45